- Principle: Nephelometry / Turbidimetry.
- Parameters: d-dimer, ferritin, HbA1c, MA, CRP, ASO, RF, C3, C4, IgE.
- Accessories:
- Incubator.
- Pipettes: (2-20) (20-200) (100-1000).
- Inbuilt thermal (58 nm) printer.
- Data Storage: 500 results.
- Lot specific assay smart card secures master calibration, optimized mixing and accurate readding of reaction.
- Use a control to check the result.
From parsian
tab zaman.
360-degree rotation.
Suitable for ESR tubes.
Up to 30 channels.
From parsian tab zaman instrments.
Model:BRM-7000 Puls.
Compute total bilirubin.
Range: 0~20 mg/dl.
Sample less than 70uL.
Dual wavelength:450nm and 546nm.
Ditector: Photodiode.
Cuvette: hematocrit tubes.
Long time stable.
Analysis time less than 5 sec.
Repeatability= +- 0.25 mg/dL.
Accuracy: +- 2%.
Dismission: (30*20*15)cm.
Weight: 2.5 kg.
.From micro lab instrument.
User friendly software.
End point method - Storage of abs of regent blank in memory / 10 graphs for KIN test.
Triplicate calibration mode for EP / KIN / Fix time.
Triplicate mode of sampling with mean / SD / CV.
Print out of laboratory and doctor's name.
For kinetic test: On line graph and OD, graph editing facility, estimation of result.
Air purge between samples to avoid carry over / lamp saver mode.
35 Direct test keys for test selection.
Utility mode for self diagnosis checking / 16 bit ADC.
Sample type: serum / plasma / CSF / urine / whole blood / hemolysate.
Calculator for lipid profile / globulin ratio / S. Iron TIBC / bilirubin.
From micro lab instrument.
User friendly software.
Cut-off and Multi standard Method.
Storage of cutoff factor & curve in memory.
Universal input voltage 95 to 265 V/50 - 60 Hz.
Storage of 1000 test results in the memory with patient ID.
LED Lamp.
Print out - storage of multi-standard curve.
From micro lab instruments.
User friendly icon based operation integrated with advanced microprocesor.
Calibration cycle: Automatic of programmable: 2hrs / 4 hrs / 6 hrs, standby mode.
Liquid stable reagents - RFID reagent management inbuilt.
Maintenance free ION SELECTIVE ELECTRODES.
Universal input voltage 95 to 265 V / 50-60 Hz.
Easy access for electrode assembly.
Automatic flagging for low/normal/high results with color code.
From micro lab instrument.
Semi-automatic Single channel coagulometer.
Printout of the graph and results.
On-board storage capability up to 20 assays.
Open system with user friendly software.
All methods creatable, editable, copy and delete.
Automated calculation results in seconds, %, INR, g/l, mg/dl, Ratio.
Calibration/reference curves editable up to 9 measurement points.
Automatic start-pipette connectable.
Automated cuvette detection and calculation.
Data transmission to SD-card or external PC (Optional).
From micro lab instrument.
Semi-automatic Single channel coagulometer.
Printout of the graph and results.
On-board storage capability up to 20 assays.
Open system with user friendly software.
All methods creatable, editable, copy and delete.
Automated calculation results in seconds, %, INR, g/l, mg/dl, Ratio.
Calibration/reference curves editable up to 9 measurement points.
Automatic start-pipette connectable.
Automated cuvette detection and calculation.
Data transmission to SD-card or external PC (Optional).
From labcare diagnostic.
Dual system of nephelometry and turbidimetric test with higher sensitivity and wider testing range.
Single channel or dual channel, tests specimens independently in different programmes.
Auto point-of-care Testing.
Touch screen, easy operation and mixing automatically recognize blank and calculate results.
Optional specimen types. Specimen dilution ratios can be input and convert result automatically.
RF
non-contact card with saved reagents parameters.
Show all the results on the screen, easy to print.
Test: ASOt, creactive protein (CRP), rhomatid factor (RF), HbA1c, microalbumin (MA), and Vitamin D.
Coming soon Tests: Ferritin, D-dimmer, IgG, IgM, and C3.
.








